fix: V8.4.5 — room-map.json Router-Instanz + Telemetrie-Logging + Kontext-Keyword Butler

Root Cause Analysis:
- BEFUND 1: room-map.json was missing from disk (deleted after M13 GC).
  Restored from version 2 backup with all 5 rooms, updated to version 5.
  Added 'sony' to DM keywords_context for Kontext-Keyword matching.
- BEFUND 2: routing_telemetry.py logger had no StreamHandler and relied
  on root logger propagation. Root logger at WARNING (gateway default)
  filtered all logger.info() calls. Fixed by adding StreamHandler at
  DEBUG level with propagate=False (same pattern as adapter.py and
  adapter_integration.py).

Changes:
- routing_telemetry.py: Add StreamHandler + setLevel(INFO) + propagate=False
- test_v8_4_5.py: 13 new tests (RoomMap loading, telemetry logging,
  Kontext-Keyword Butler, regression)
- test_v8_3_3.py: Fix 4 existing telemetry tests to temporarily enable
  propagation for caplog capture
- test_room_map.py: Fix test_no_env_vars to clear ARCHIVAR_* env vars
  before assertion

Verification:
- 612 passed, 2 skipped, 0 failures
- python3 -m py_compile: all files OK
This commit is contained in:
Bernd (Hermes)
2026-07-16 09:10:30 +02:00
parent bd1c0cd327
commit da5586e776
4 changed files with 504 additions and 64 deletions
+9
View File
@@ -27,6 +27,15 @@ import time
from typing import Dict, List, Optional
logger = logging.getLogger(__name__)
logger.setLevel(logging.INFO)
# Ensure telemetry logs are visible even when root logger is at WARNING.
# adapter_integration.py and adapter.py do the same for their loggers.
if not logger.handlers:
_handler = logging.StreamHandler()
_handler.setLevel(logging.DEBUG)
_handler.setFormatter(logging.Formatter('%(asctime)s %(levelname)s %(name)s: %(message)s'))
logger.addHandler(_handler)
logger.propagate = False # Don't double-log to root